fire extinguisher

Emergency! Where’s The Fire Extinguisher?

Emergency! Where’s the Fire Extinguisher?

A fire can grow rapidly. Knowing where fire extinguishers are located, what type to use, and when to evacuate instead of attempting to fight a fire can prevent a small emergency from becoming a serious injury or fatality.

Imagine walking toward the maintenance shop and smelling something burning. You see smoke coming from a window and discover a trash container on fire. What should you do?

Before attempting to use an extinguisher, quickly consider:

  • Has the fire alarm or emergency notification been activated?
  • Have employees in the area been warned?
  • Has the fire department or designated emergency contact been notified?
  • What material is burning?
  • Do you have the correct type of extinguisher?
  • Is the fire small and contained?
  • Do you have a clear and unobstructed escape route behind you?
  • Have you been trained and authorized to use a portable fire extinguisher?

Never attempt to fight a fire if doing so could prevent your safe escape.

Know the Classes of Fire

Different materials require different types of extinguishing agents. Using the wrong extinguisher can be ineffective and, in some situations, dangerous.

Class A – Ordinary Combustibles
Includes materials such as:

  • Wood
  • Paper
  • Cloth
  • Many plastics
  • Trash and similar ordinary combustible materials

Class B – Flammable Liquids and Gases
Includes materials such as:

  • Gasoline
  • Oils
  • Grease
  • Paints and solvents
  • Other flammable or combustible liquids

Class C – Energized Electrical Equipment
Includes fires involving energized:

  • Electrical panels
  • Motors
  • Wiring
  • Appliances
  • Electrical tools and equipment

Class C extinguishing agents are nonconductive. Once electrical equipment has been safely de-energized, the remaining fire is treated according to the material that continues to burn.

Class D – Combustible Metals
Includes certain combustible metals such as magnesium, titanium, sodium, and potassium. These fires require extinguishing agents specifically designed for the metal involved.

Class K – Cooking Oils and Fats
Primarily associated with commercial cooking operations involving vegetable oils, animal oils, or fats. Class K extinguishers are specifically designed for these hazards.

Many workplaces use multipurpose ABC dry chemical extinguishers, but never assume an extinguisher is suitable for every fire. Read the extinguisher label before an emergency occurs.

Before You Fight a Fire

Portable fire extinguishers are intended primarily for small, incipient-stage fires. Employees should attempt to extinguish a fire only when permitted by company procedures and when they have been trained to do so.

Before using an extinguisher:

  • Sound the alarm and warn people in the area.
  • Ensure emergency responders have been or are being notified.
  • Identify what is burning.
  • Select the proper extinguisher.
  • Make sure the fire is small and has not spread beyond the immediate area.
  • Stay away from heavy smoke, toxic fumes, and rapidly spreading flames.
  • Position yourself with a clear escape route behind you.

If the fire is spreading, producing significant smoke, threatening hazardous materials, or blocking your escape route, evacuate immediately and leave firefighting to trained emergency responders.

Remember PASS

When trained and authorized to use a portable fire extinguisher, remember PASS:

P – Pull the pin.
A – Aim the nozzle at the base of the fire.
S – Squeeze the operating handle.
S – Sweep from side to side at the base of the fire.

Continue watching the area after the flames appear to be extinguished. A fire may reignite.

Do not turn your back on the fire while leaving the area.

Keep Extinguishers Accessible

Do you know where the nearest fire extinguisher is right now?

Fire extinguishers must be readily accessible when needed. Never:

  • Block an extinguisher with equipment or stored materials.
  • Hang coats, tools, or other objects over an extinguisher.
  • Remove an extinguisher from its designated location except for authorized use, inspection, or servicing.
  • Tamper with extinguisher pins, seals, hoses, or identification labels.

Employees should become familiar with extinguisher locations and types before an emergency occurs.

Inspection and Readiness

Portable extinguishers should be visually inspected regularly to ensure they are ready for use. Check that:

  • The extinguisher is in its designated location.
  • Access is unobstructed.
  • The operating instructions are legible and facing outward.
  • The pin and tamper seal are intact.
  • The hose and nozzle are unobstructed and undamaged.
  • There are no obvious signs of corrosion, leakage, or physical damage.
  • The pressure indicator, when provided, shows the extinguisher is properly charged.

Report damaged, discharged, missing, or improperly charged extinguishers immediately.

Remember

Your first responsibility during a fire is life safety—not saving equipment, materials, or the building. Know your company’s emergency procedures, know the location and type of nearby extinguishers, and know when to evacuate.

If there is any doubt about whether you can safely control the fire, evacuate, keep others away, and call the fire department.