confined space

The Silent Dangers of Confined Space

The Silent Dangers of Confined Spaces

Confined spaces can contain serious hazards that cannot be detected by sight, smell, or taste. An atmosphere may appear completely normal while containing too little oxygen, toxic gases or vapors, or a flammable atmosphere capable of causing serious injury or death.

Never assume a confined space is safe because someone else has checked it, because it was safe previously, or because the air smells normal. Atmospheric conditions can change rapidly, particularly when work is being performed inside the space.

Guide for Discussion

Recognize Confined Spaces

Confined spaces may include:

  • Tanks and vessels.
  • Manholes and vaults.
  • Sewers and storm drains.
  • Pipelines.
  • Tunnels and pits.
  • Storage bins and silos.
  • Process vessels and mixing tanks.
  • Other enclosed or partially enclosed spaces with limited means of entry or exit.

Before work begins, the employer must evaluate the workplace to determine whether confined spaces are present and whether they meet the requirements for a permit-required confined space.

Know the Atmospheric Hazards

A confined space may contain one or several atmospheric hazards, including:

  • Oxygen deficiency – too little oxygen to safely support life.
  • Oxygen enrichment – excessive oxygen that can greatly increase fire hazards.
  • Flammable gases, vapors, or combustible dusts that could ignite or explode.
  • Toxic gases and vapors, such as hydrogen sulfide or carbon monoxide.
  • Contaminants created by welding, cutting, painting, cleaning, chemical use, or other work performed inside the space.

Never rely on your senses to determine whether an atmosphere is safe.

Test Before Entry

Before an employee enters a permit-required confined space, the internal atmosphere must be tested with properly calibrated direct-reading instruments.

Atmospheric testing should generally be performed in this order:

  1. Oxygen content.
  2. Flammable gases and vapors.
  3. Potential toxic air contaminants.

Testing should be performed from outside the space before entry whenever possible. Because contaminants may collect at different levels, atmospheric testing may need to be performed at the top, middle, and bottom of the space.

Employees must not enter until required testing has been completed and acceptable entry conditions have been established.

Monitor the Atmosphere

Atmospheric conditions can change after entry. Welding, cutting, cleaning, painting, chemical use, disturbing sludge, or other work may introduce new hazards.

The atmosphere must be tested or monitored as necessary to ensure acceptable entry conditions are maintained throughout the entry operation. When conditions warrant, continuous atmospheric monitoring should be used.

If a hazardous atmosphere develops or acceptable entry conditions cannot be maintained, employees must exit the space immediately.

Ventilation and Hazard Control

Where ventilation is used to control atmospheric hazards:

  • Use clean air from an uncontaminated source.
  • Position ventilation equipment to effectively ventilate the work area.
  • Continue ventilation as necessary to maintain acceptable conditions.
  • Do not introduce oxygen into the space as a substitute for fresh-air ventilation.
  • Protect ventilation equipment and ducting from damage.
  • Continue atmospheric monitoring to verify that ventilation is effective.

Other hazards—including electrical, mechanical, hydraulic, pneumatic, chemical, engulfment, and stored-energy hazards—must also be identified and controlled before entry.

Permit-Required Confined Spaces

Entry into a permit-required confined space must follow the company’s established confined-space entry program. Depending on the hazards, this may require:

  • A completed entry permit.
  • An authorized entrant.
  • An attendant stationed outside the space.
  • A designated entry supervisor.
  • Atmospheric testing and monitoring.
  • Isolation and lockout/tagout of hazardous energy.
  • Ventilation.
  • Required PPE.
  • Appropriate communication equipment.
  • Barriers to protect the entry area.
  • Retrieval and rescue equipment.
  • An established emergency and rescue procedure.

Never enter a permit-required confined space unless you are trained, authorized, and all required entry procedures have been completed.

Confined-Space Rescue

confined space

Many confined-space fatalities involve would-be rescuers who enter without proper equipment or training.

Never enter a confined space to rescue another worker unless you are a trained and properly equipped member of the designated rescue service and the required rescue procedures are being followed.

When required, non-entry retrieval systems should be used so an entrant can be rescued without another employee entering the hazardous space.

Immediately summon the designated rescue service when an emergency occurs. Do not allow an emergency to turn one victim into several.

Remember

A confined space does not have to look, smell, or feel dangerous to be deadly. Never trust your senses to determine whether the atmosphere is safe.

Test before entry, continuously evaluate conditions, follow the entry permit when required, and never attempt an unauthorized confined-space rescue.